Azure Camera-based Imaging Systems
Azure's top model, the Azure 600 eliminates the need for multiple instruments by combining laser-based NIR fluorescence, visible RGB fluorescence, and high-sensitivity chemiluminescence in one device. It minimizes footprint, yet supports everything from standard DNA gels to complex multiplex Western blots and even 3D samples like small animal models. As the range is modular, you can start with a system that fits your current needs, and upgrade as your research takes you to new applications.
| Article Code | Description |
| AZI600-01 | Azure 600 |
| AZI500-01 + AZI50Q | Azure 500Q |
| AZI500-01 | Azure 500 |
| AZI400-01 | Azure 400 |
| AZI300-01 + AZI30Q | Azure 300Q |
| AZI300-01 | Azure 300 |
| AZI280-01 | Azure 280 |
| AZI200-01 | Azure 200 |
Contact Bart Vleugels your Life Sciences expert
Resources
Have product questions?
Azure 600
The Ultimate Multimodal Imaging System for Quantitative Western Blotting
The Azure 600 is a comprehensive imaging workstation designed to eliminate the need for multiple instruments. It combines laser-based near-infrared (NIR) fluorescence, three-channel RGB fluorescence, and high-sensitivity chemiluminescence detection. With a 9.1 MP camera and 4.8 OD dynamic range, it provides the precision required for publication-quality data and robust quantitation.
Quantitative NIR Fluorescence
Utilize two-channel laser-based infrared detection for multiplex Western blotting, allowing for simultaneous probing of multiple targets or loading controls.
RGB & Visible Imaging
Three-channel RGB detection supports a wide variety of fluorescent dyes (Cy5/Cy3/Cy2) for multiplexing in the visible spectrum.
Gel Documentation
Built-in UV and blue light transilluminators support standard DNA and protein gel imaging, including EtBr and stain-free workflows.
Scalable Performance through Field Upgrades
The Azure cSeries architecture is designed to evolve with your laboratory's changing needs. Every system, from the entry-level Azure 200 to the specialized Azure 500, can be upgraded in the field to the full multimodal capabilities of the Azure 600. This modular design ensures that you can start with the specific detection technology you need today—such as standard gel documentation or chemiluminescence—and add NIR or RGB fluorescence later without the cost of a new instrument.
Future-Proof Your Research
Parameter | Azure 600 | Azure 500 | Azure 400 | Azure 300 | Azure 280 | Azure 200 |
Detection | 9.1 MP camera | 9.1 MP camera | 9.1 MP camera | 9.1 MP camera | 6.1 MP camera | 5.4 MP camera |
Pixel Resolution | 16-bit Grayscale | 16-bit Grayscale | 16-bit Grayscale | 16-bit Grayscale | 16-bit Grayscale | 16-bit Grayscale |
Peltier Cooling | -50°C regulated | -50°C regulated | -50°C regulated | -50°C regulated | -50°C regulated | N/A |
Dynamic Range | Up to 24-bit | Up to 24-bit | Up to 24-bit | Up to 24-bit | Up to 24-bit | Standard |
Filter Wheel | 7 Position | 7 Position | 7 Position | 7 Position | 7 Position | 7 Position |
Trans UV (302/365nm) | Included | Included | Included | Included | Included | Included |
Color Imaging | Included | Included | Included | Included | Included | Included |
Epi-white Imaging | Included | Included | Included | Included | Included | Included |
Trans-white Imaging | Included | Included | Included | Included | Included | [UNCONFIRMED] |
Chemiluminescence | Included | Included | Included | Included | Included | N/A |
Laser NIR Imaging | Included | N/A | N/A | N/A | N/A | N/A |
Visible/RGB Fluorescent | Included | Included | N/A | N/A | N/A | N/A |
Epi Blue Light | Included | Included | Included | Included | Included | Included |
Protein Normalization | Included | Optional | Included | Optional | [UNCONFIRMED] | [UNCONFIRMED] |
Field of View | 20.5 x 16.5 cm* | 20.5 x 16.5 cm* | 20.5 x 16.5 cm* | 20.5 x 16.5 cm* | 20.4 x 16.6 cm* | 20 x 15 cm* |
Dimensions (WxHxD) | 42 x 56 x 33 cm | 42 x 56 x 33 cm | 42 x 56 x 33 cm | 42 x 56 x 33 cm | 42 x 56 x 33 cm | 42 x 56 x 33 cm |
Weight | 20 kg | 20 kg | 20 kg | 20 kg | 20 kg | 17.7 kg |
Power | 100-240 VAC | 100-240 VAC | 100-240 VAC | 100-240 VAC | 100-240 VAC | 100-240 VAC |
- Laser-Based NIR Multiplexing
- 9.1 MP High-Resolution Imaging
- Chemiluminescence & RGB Versatility
- 4.8 OD Quantitative Dynamic Range
- Modular Field-Upgradable Design
- Laser-Based NIR Multiplexing
- 9.1 MP High-Resolution Imaging
- Chemiluminescence & RGB Versatility
- 4.8 OD Quantitative Dynamic Range
- Modular Field-Upgradable Design
Azure 600 Frequently Asked Questions
Technical and operational insights for the Azure 600 multimodal imaging system and its integration within the cSeries product family.
The Azure 600 is the most comprehensive system in the range, offering laser-based NIR fluorescence, three-channel RGB fluorescence, and high-sensitivity chemiluminescence. While models like the Azure 400 (visible-only) or Azure 500 (NIR-only) specialize in specific spectra, the Azure 600 integrates all these modalities into a single workstation for maximum application flexibility.
Yes. A core advantage of the cSeries architecture is its field-upgradability. Systems such as the Azure 300, 400, or 500 can be upgraded in your laboratory to add NIR or visible fluorescence capabilities, effectively bringing them to the Azure 600 performance level as your research requirements evolve.
Accuracy is driven by a 9.1 MP CCD camera and a broad 4.8 OD dynamic range, which prevents signal saturation of high-abundance proteins while maintaining sensitivity for low-abundance targets. Additionally, the laser-based NIR excitation ensures lower background interference compared to LED systems, which is critical for robust quantitation.
The system supports a wide array of media including membranes, synthetic gels, bacterial plates, and even small animal models. It is compatible with standard dyes like Cy2/Cy3/Cy5 for RGB multiplexing and common NIR dyes (e.g., IRDye 680/800) for deep-red fluorescence applications.
No. The Azure 600 and 500 laser systems are designed to be maintenance-free. They do not require periodic adjustments or user-led calibrations to maintain optimal performance. The lasers are fully enclosed and interlocked for safety, ensuring consistent excitation power over the life of the instrument.
By utilizing up to four distinct fluorescent channels (NIR and RGB), the Azure 600 allows for the simultaneous detection of multiple targets on the same blot. This enables the resolution of co-migrating bands, such as phosphorylated versus total protein forms, which cannot be achieved with traditional chemiluminescence alone.
