Back to
Life Sciences

Tagify™ Loaded Transposase Reagents

Quality-controlled loaded transposase for reproducible NGS library preparation.
seqWell NGS Library Prep & Controls

Whether you are scaling up a standardized CRISPR QC assay or developing a novel sequencing method from the ground up, the Tagify™ line provides the high-performance, ready-to-use transposase reagents you need to eliminate the "homebrew" headache.

Depending on your specific research goals, we offer two distinct pathways to success:

  • Tagify™ i5 UMI Adapter-loaded: Our streamlined, off-the-shelf solution. Pre-loaded with Illumina-compatible adapters and Unique Molecular Identifiers (UMIs), this is the gold standard for high-throughput, quantitative gene-editing analysis.
  • Tagify™ Custom-loaded: Our bespoke service for specialized applications. Work with our team to load our hyperactive Tn5 or low-bias TnX™ enzymes with your proprietary oligo sequences, tailored specifically to your unique library prep architecture.

Explore the options below to find the right fit for your lab.

FeatureSpecification
Transposase EnzymeHyperactive Tn5
Adapter PayloadP5 + i5 + UMI + R1 (82 bp total)
Barcoding10 bp i5 barcode; 10 bp UMI
Sample Input TypeGenomic DNA (gDNA)
Recommended DNA Input50 ng
Output Fragment Range800 – 2,000 bp (Measured via Agilent Bioanalyzer)
Sequencer CompatibilityAll Illumina platforms; Element Biosciences AVITI™ (with conversion)
FeatureSpecification
Transposase EnzymeHyperactive Tn5 ór TnX
BarcodingCustom
Sample Input TypeGenomic DNA (gDNA)
Recommended DNA InputDependent on desired application
Output Fragment RangeFragment range designed to meet customer needs
ReagentArticle NumberDescription

Tagify™ i5

301230Tagify™ i5 UMI 24 (1x24x3µL) Reagent set
Tagify™ i5301251Tagify™ i5 UMI 24 (4x24x3µL) Reagent set
Tagify™ i5301253Tagify™ i5 UMI 24 (1x24x4µL) Reagent set
Tagify™ i5301255Tagify™ i5 UMI 24 (4x24x3µL) Reagent set

Tagify™ Custom

301520Tagify™ Custom TnX A14
Tagify™ Custom301521Tagify™ Custom TnX B15
Tagify™ Custom301530Tagify™ Custom Tn5 - level 2
Tagify™ Custom301531Tagify™ Custom TnX - level 2

Contact Thomas Dammers your Life Sciences expert

Your personal advisor for the right products and solutions.

Resources


Have product questions?

Our experts are here to guide you. Whether you have questions about workflows, certifications, compatibility, or product selection — we’re just one click away.
Supplier

Tagify™ i5 UMI Adapter-loaded Transposase

The Tagify™ i5 UMI Adapter-loaded Transposase provides a commercial, off-the-shelf source of hyperactive Tn5 transposase, pre-loaded with full-length Illumina-compatible P5+i5+UMI+R1 sequences. This reagent eliminates the need for manual enzyme purification and loading, significantly reducing assay-to-assay variability in NGS-based on- and off-target analysis.

With a 10-bp i5 barcode and a 10-bp UMI, this solution supports high-throughput multiplexing and precise molecular counting for sensitive genomic assays.

The reagent catalyzes a simultaneous fragmentation and tagging reaction. DNA is prepared for downstream assays in a single 15-minute incubation step followed by a standard bead-based clean-up.

Applications

Versatile Solutions for Genomic Analysis

Gene Editing QC

Validated for use in CRISPR QC, measuring large deletions, inversions, and translocations.

Targeted Assays

Supports UDiTaS™, RGEN-seq, TTIS-seq, and CHANGE-seq methods.

High-Plex Scaling

Available with up to 96 unique UMIs to support large-scale sample multiplexing.

Tailored Tagmentation for Specialized Assays

Tagify™ Custom Adapter-loaded Transposase

The Tagify™ Custom-loaded Transposase service provides researchers with access to seqWell’s TnX transposase or hyperactive Tn5 enzyme loaded with proprietary or specialized adapter sequences. This service eliminates the technical challenges of in-house loading, providing a ready-to-use reagent that ensures high efficiency and reproducibility for bespoke NGS workflows.

seqWell's team works with you to verify your adapter designs. Once finalized, seqWell performs the loading and quality control, delivering a stabilized transposase optimized for your specific application.

Expert Support

Custom Solutions for Your Assay

Do you have specific requirements for your adapter sequences or need assistance designing a custom workflow? Our technical specialists are ready to help you configure the ideal Tagify™ solution for your research.

Reagent Specifications & Experimental Validation

Technical details regarding the Tagify™ i5 UMI reagent set, including kit components, fragmentation performance, and validation protocols for NGS workflows.

The standard Tagify i5 UMI 24 reagent set includes: 1x24x3uL of Tn5s (each loaded with a p5, unique UMI, and unique i5) dispensed into a 96-well plate, 1x1.5mL bottle of 3X Coding Buffer, 2x1.2mL bottle of X Solution, and 1x5mL MAGWise magnetic purification beads.

The UMI and i5 are 10bp each.

seqWell has validated a matching set of i7 index sequences that can be used in combination with the i5 indexes included. This can be found on the Tagify i5 UMI master index list.

The reagents have been tested for multiple freeze-thaw cycles without issue. To use less than the full reaction plate of Tagify i5 UMI reagent, it is recommended to use a scalpel or razor blade to only open and peel the heat seal from the wells of the Tagify i5 UMI Reagent Plate corresponding to the total number of samples that will be processed. Please refer to the user guide for more detailed instructions.

  • The Tagify i5 UMI reagent should generate 800 - 2000 bp fragments when following the standard protocol using 50 ng of high quality gDNA input with the 2μl (Standard 1X) Tagging Reaction.
  • If different fragment sizes are required by your downstream assay, please follow our Tagify i5 UMI Titration Transposase Reagent and Input DNA Titration technical note

Each well in the plate contains enough reagent for 1 reaction.

The Tagify i5 UMI reagent is designed for use in a variety of downstream applications that require the addition of a UMI. These reagents may be incorporated as part of targeted sequencing assays, such as UDiTaS1 or RGen Seq2 applications, CRISPR QC, and Cell and Gene Engineering QC. However, commercial use of these reagents in sequencing activities may require a license from a third party.

The Tagify i5 UMI reagent generates a one-sided tagged fragment and will still need an additional barcode for sequencing.

  1. seqWell defines successful use of the Tagify i5 UMI reagent as tagging 50ng of genomic DNA input to 800-2000bp fragments, measured by the Agilent High Sensitivity DNA Bioanalyzer Chip, when following the standard protocol. You can find an example trace of this fragmentation in the user guide under “Tagged DNA QC & Quantification”. Other QC assays and instruments are not supported for this reagent due to significant size discrepancies found when using assays, such as the Agilent TapeStation HS D5000 Screen Tape.
  2. If you wish to validate the success of this reagent, we recommend following the standard 1X protocol with 50ng of control human gDNA, such as NA1278, and observing the fragment size on the Bioanalyzer.
  3. Please note that, due to the wide variation in potential downstream assays3, seqWell is unable to support the success of any assay following successful tagmentation with this reagent. To validate the success of non-seqWell assays we recommend following any respective control assays outlined in their methods.

Resources Tagify™ i5

Tagify™ i5 Technical Specifications

Download

Please enter your email address to download the asset.

Refreshing in

seqWell Tagify™ Tiration & input DNA technical note

Download

Please enter your email address to download the asset.

Refreshing in

Tagify™ i5 UMI Master Index List

Download

Please enter your email address to download the asset.

Refreshing in

Downloads

Tagify™ i5 UMI Loaded Transposase Reagent brochure

Download

seqWell Tagify™ Reagent Comparison Guide

Download

seqWell Tagify i5 UMI User Guide

Download